[1]王梦鸽,邓 渊,刘建林,等.面向输电线路的集成化在线监测装置设计[J].工业仪表与自动化装置,2026,(01):46-50.[doi:10.19950/j.cnki.CN61-1121/TH.2026.01.009]
 WANG Mengge,DENG Yuan,LIU Jianlin,et al.Design of integrated online monitoring device for transmission lines[J].Industrial Instrumentation & Automation,2026,(01):46-50.[doi:10.19950/j.cnki.CN61-1121/TH.2026.01.009]
点击复制

面向输电线路的集成化在线监测装置设计()

《工业仪表与自动化装置》[ISSN:1000-0682/CN:61-1121/TH]

卷:
期数:
2026年01期
页码:
46-50
栏目:
出版日期:
2026-02-15

文章信息/Info

Title:
Design of integrated online monitoring device for transmission lines
文章编号:
1000-0682(2026)01-0046-05
作者:
王梦鸽邓 渊刘建林张建峰张凯丽
平高集团有限公司,河南 郑州 450046
Author(s):
WANG Mengge DENG Yuan LIU Jianlin ZHANG Jianfeng ZHANG Kaili
Ping Gao Group Co., Ltd., Zhengzhou , China)
关键词:
间隔棒输电线路监测集成化设计无线取能并行采样
Keywords:
Spacer Transmission line monitoring Integrated design Wireless energy acquisition Parallel sampling
分类号:
TH811TM75
DOI:
10.19950/j.cnki.CN61-1121/TH.2026.01.009
文献标志码:
A
摘要:
针对超高压输电线路数字化转型需求,文中以输电线路在线监测技术为研究对象,设计提出了一种集成于四分裂间隔棒的超高压输电线路在线监测装置。该装置采用传感取能线夹与控制器一体式架构设计,实现了对于电流、温度的实时监测,并通过5G通信实现数据高速回传。基于双C型磁芯设计的CT取能单元,实现了20 A时8 W额定功率输出,并具备CT部分失效冗余能力。利用GPS与北斗双模授时同步的并行ADC采样方法,将时钟误差控制在ppb级,确保四通道暂态电流可达到微秒级的同步精度。实验测试结果表明,该装置的工频稳态电流误差<5%,暂态电流峰值误差<10%,温度监测精度达±1℃,能够直接替换传统的间隔棒,为输电线路提供了一种集成化的智能监测解决方案。
Abstract:
In response to the demand for digital transformation of ultra-high voltage transmission lines, this paper takes online monitoring technology of transmission lines as the research object, and designs and proposes an integrated ultra-high voltage transmission line online monitoring device with four split spacers. The device adopts an integrated architecture design of sensing and energy harvesting clamp and controller, which realizes real-time monitoring of current and temperature, and achieves high-speed data transmission through 5G communication. The CT energy harvesting unit based on the design of dual C-type magnetic cores has achieved a rated power output of 8W at 20A and has the capability of CT partial failure redundancy. Using the parallel ADC sampling method of GPS/Beidou dual-mode timing synchronization, the clock error is controlled at ppb level to ensure microsecond level synchronization accuracy of the four channel transient current. The experimental test results show that the device has a steady-state current error of less than 5%, a peak current error of less than 10%, and a temperature monitoring accuracy of ±1℃. It can directly replace traditional spacers and provide an integrated intelligent monitoring solution for transmission lines.

参考文献/References:

[1]龚培林,魏敏,严波,等.基于多物理场的输电线路在线监测装置内部温湿度控制方法研究[J].电气自动化,2024,46(6):55-57.

[2]毕含嘉,杨楚睿,王小雨,等.基于改进YOLOv7的输电线路多类缺陷目标检测[J].电子科技,2025,38(4):16-24.
[3]涂婧琳,王洪亮.基于IAOA-LSSVM的输电线路覆冰厚度预测研究[J].现代电子技术,2024,47(21):113-118.
[4]何智强,牛捷,刘兰兰,等.基于分布式电流行波监测的输电线路故障精确定位装置研制[J].科学技术与工程,2023,23(18):7798-7808.
[5]蔡光柱,李军辉,倪康婷,等.基于物联网技术的覆冰舞动综合监测装置设计[J].电力安全技术,2023,25(8):37-40.
[6]廖如超,刘高,汪皓,等.输电线路外破隐患空间距离三维点云测量方法[J].沈阳工业大学学报,2025,47(1):14-20.
[7]何柏娜,代维汉,荣博,等.高压输电线路电磁感应取能电源优化设计[J].电工技术,2024(5):174-179.
[8]汤春俊,梁加凯,朱凯,等.基于DSP的输电线路四分裂间隔棒安装检修机器人自动巡检技术[J].制造业自动化,2022,44(8):162-165.
[9]沈畅,贾雅君,金之俭,等.基于MEMS光纤传感器的油浸式电流互感器在线监测技术[J].电测与仪表,2025,62(9):166-175.
[10]陶雄武,周俊宏,陈德权,等.电流互感器饱和误差二次补偿方法研究[J].自动化仪表,2025,46(4):12-16.
[11]唐海博,潘建宇,姜怡,等.高压SiC装备高频电流互感器型隔离取能电源电场分布和绝缘特性[J].电工技术学报,2025,40(10):3170-3180,3273.
[12]郭志弘.双通道时间交织ADC采样系统的模拟前端驱动芯片设计[D].成都:电子科技大学,2024.
[13]陈逸风,高树静,秋小强,等.基于AHB总线的全双工DMA控制器设计[J].电子设计工程,2025,33(10):1-5.
[14]杨国伟,张多利,王宇.GPS信号的捕获算法研究与硬件实现[J].合肥工业大学学报(自然科学版),2025,48(4):475-481.
[15]杨洪旭,郭鹏超,宋文涛.北斗卫星导航系统在电力工程中长基线控制测量中的精度分析[J].测绘与空间地理信息,2025,48(S1):49-52.
[16]王珂,邓连生,田金泽,等.北斗与GPS伪距单点定位精度的比较分析[J].湖北理工学院学报,2023,39(3):1-6.?/div>

相似文献/References:

备注/Memo

备注/Memo:
收稿日期:2025-06-27基金项目:平高集团科技项目(PGKJ2023-004)。第一作者:王梦鸽(1997—),女,河南许昌人,硕士,助理工程师,研究方向为电力设备智能监测。
更新日期/Last Update: 1900-01-01