|本期目录/Table of Contents|

[1]张 楠,葛月霆,张 雷.蒸汽大气排放系统(TSA)大气排放阀30分钟不干预自动控制方案设计[J].工业仪表与自动化装置,2020,(06):35-38.[doi:1000-0682(2020)06-0000-00]
 ZHANG Nan,GE Yueting,ZHANG Lei.Design of Atmospheric Steam dump system(TSA)Atmospheric steam dump valves 30 minutes nonintervention automatic control[J].Industrial Instrumentation & Automation,2020,(06):35-38.[doi:1000-0682(2020)06-0000-00]
点击复制

蒸汽大气排放系统(TSA)大气排放阀30分钟不干预自动控制方案设计

《工业仪表与自动化装置》[ISSN:1000-0682/CN:61-1121/TH]

卷:
期数:
2020年06期
页码:
35-38
栏目:
出版日期:
2020-12-15

文章信息/Info

Title:
Design of Atmospheric Steam dump system(TSA)Atmospheric steam dump valves 30 minutes nonintervention automatic control
作者:
张 楠葛月霆张 雷
中国核电工程有限公司,北京 100840
Author(s):
ZHANG Nan GE Yueting ZHANG Lei
China Nuclear Power Engineering Co.LTD.,Beijing 100840,China
关键词:
大气排放阀30分钟不干预多样化控制
Keywords:
Atmospheric steam dump valves 30 minutes nonintervention automatic control diverse control
分类号:
TM623
DOI:
1000-0682(2020)06-0000-00
文献标志码:
B
摘要:
该文介绍了华龙一号核电站大气排放阀自动控制方案。该控制方案主要实现了安注信号自动触发大气排放阀进行自动调节,完成反应堆冷却剂回路快速冷却,30分钟内,无需任何操纵员干预,自动将压力定值从7.85 MPa(a)逐步调整到4.5 MPa(a),维持一回路以一定的冷却速率的自动调节方案的设计,这种控制方案大大降低了紧急事故下由于人员误判误操为反应堆带来的安全风险。文中详细介绍了蒸汽大气排放系统(TSA)大气排放阀的系统运行要求、控制要求、30分钟不干预自动控制方案实现和应对控制系统共模故障的多样化手动控制实现方案。
Abstract:
A method of atmospheric Steam dump valve control in HPR1000 nuclear power plant is introduced. This control method can realize that the atmospheric Steam dump valve is automatically controlled when receiving the safety injection(SI)signal,In 30 minutes,no need the operator, the set point of the atmospheric Steam dump valve is automatically set from 7.85 MPa(a)to 4.5 MPa(a)to cool the reactor at a rate. This control method reduce the risk of the operator wrong decide on emergency conditions. Detailed description of the atmospheric Steam dump system(TSA)steam dump valves system requirement,control requirement,automatically control design method, diverse manual control is introduced in the paper.

参考文献/References:

[1] 核工业第二研究设计院. RCC-E 压水堆核电站核岛电气设备设计和建造规则[M]. 1993.

[2] 李溪韵. 核级调节控制在出口核电项目中的实现[J]. 科技资讯, 2014, 12(13):206-208.
[3] 毛从吉,毋琦.从安全评审角度看核电站数字化仪控设计[J]. 自动化仪表,2012,33(7):39-42.
[4] 梁玲, 张黎明, 李静. 核电厂安全级模拟量调节逻辑退化方法研究[J]. 核科学与工程, 2011,31(S2):101-104.

相似文献/References:

备注/Memo

备注/Memo:
收稿日期:2020-05-18
作者简介:张楠(1981),男,河北保定人,高级工程师,主要研究方向为核电厂仪控设计。
更新日期/Last Update: 1900-01-01