|本期目录/Table of Contents|

[1]苌飞霸,陈维平,徐 力,等.基于光电容积脉搏波法血氧饱和度测量系统研究[J].工业仪表与自动化装置,2015,(05):14.
 CHANG Feiba,CHEN Weiping,XU Li,et al.A research of blood oxygen saturation measurement system based on the photoplethysmography method[J].Industrial Instrumentation & Automation,2015,(05):14.
点击复制

基于光电容积脉搏波法血氧饱和度测量系统研究(PDF)

《工业仪表与自动化装置》[ISSN:1000-0682/CN:61-1121/TH]

卷:
期数:
2015年05期
页码:
14
栏目:
出版日期:
2015-10-15

文章信息/Info

Title:
A research of blood oxygen saturation measurement system based on the photoplethysmography method
文章编号:
1000-0682(2015)05-0000-00
作者:
苌飞霸陈维平徐 力尹 军*
(第三军医大学大坪医院野战外科研究所 医学工程科,重庆 400042)
Author(s):
CHANG Feiba CHEN Weiping XU Li YIN Jun*
(Medical Engineering Department, Institute of Surgery Research, Daping hospital, The Third Military Medical University, Chongqing 400042, China)
关键词:
血氧饱和度光电容积脉搏波反射式检测无创
Keywords:
Blood oxygen saturation photoplethysmography reflective measurement non-invasive
分类号:
R444
DOI:
-
文献标志码:
A
摘要:
血氧饱和度是人体一项重要的生理参数。目前,血氧饱和度检测方法分为有创血氧饱和度检测和基于光电容积脉搏波法的无创血氧饱和度检测。其中,基于光电容积脉搏波法的无创血氧饱和度研究模型采用人体光电容积脉搏波信号作为信息载体进行无创连续的血氧饱和度的检测。该文综述了基于血液容积波法无创血氧饱和度测量原理及测量系统;重点介绍了反射式血氧饱和度检测系统;并对影响血液容积波法无创血氧饱和度测量系统准确性的相关因素进行了归纳与总结。
Abstract:
The blood oxygen saturation is an important human physiological parameter.Currently, the blood oxygen saturation detection method is divided into the invasive measurement of blood oxygen saturation and noninvasive measurement of blood oxygen saturation based on photoplethysmography method. Among them, Based on photoplethysmography method of noninvasive oxygen saturation research model adopts photoelectric volume pulse wave signals of the human body as an information carrier for noninvasive continuous blood oxygen saturation detection. This paper reviews noninvasive oxygen saturation based on photoplethysmography method measurement principle and measurement system; mainly introduces the reflectance oxygen saturation detection system; and the related factors affecting the accuracy of the noninvasive blood oxygen saturation measurement system were concluded and summarized.

参考文献/References:

[1] 李晓鹏,宋爱国,彭思,等.脉搏血氧饱和度远程实时监护系统设计[J].传感技术学报,2010,23(6):772-776.

[2] 龚渝顺,吴宝明,高丹丹.一种抗干扰穿戴式血氧饱和度检测仪的研制[J].传感技术学报,2012,25(1):6-10.
[3] 谭小丹,邓亲恺,陈亚明.无损伤血氧血氧饱和度测量的研究[J].中国医学物理学杂志,1999,16(2):103- 107.
[4] 刘光达,郭维,朱平,等.基于容积波分析的血氧饱和度测量系统[J].激光与红外,2009,39(2):169-172.
[5] 江丽仪,林绍杰,吴效明.基于ZigBee的血氧饱和度检测技术与模块研制[J].中国医学物理学杂志,2010,27(1): 1672-1675.
[6] 高博,魏蔚,龚敏,等.利用近红外光谱检测多层组织血氧饱和度的研究[J].光谱学与光谱分析,2009,29(11): 2922-2925.
[7] 陈晓冰,刘辉辉,李小玲.透射式血氧饱和度检测方法研究[J].电子测试,2009,(12):15-18.
[8] 李章勇,刘亚东,王伟,等.反射式血氧饱和度检测仪的设计[J].科技信息,2013,4:75-76.
[9] 李景文,龙村,张保洲,等.反射式血氧饱和度检测仪的设计[J].北京生物医学工程, 2002,21(4):271-272.
[10] 王倩,丁虹霞,张元亭.EMD在消除光电容积脉搏波中运动伪迹的应用[J].先进技术研究通报,2010,4(6):2-6.
[11] 张虹,孙卫新, 金捷.脉搏血氧饱和度检测系统设计中干扰信号的处理方法[J].国外医学生物医学工程分册,2000, 23(2):90-94.

相似文献/References:

备注/Memo

备注/Memo:

收稿日期 2015-01-29

作者简介 :苌飞霸 (1985) ,男,硕士,第三军医大学大坪医院野战外科研究所医学工程科,主要研究方向为生物医学信号检测,传输及信息编码技术研究。

更新日期/Last Update: 1900-01-01