|本期目录/Table of Contents|

[1]张 涛,郑鸿磊,陈聪聪.中央空调冷却水系统变风量变水量节能性分析[J].工业仪表与自动化装置,2018,(06):7-11.[doi:1000-0682(2018)06-0000-00]
 ZHANG Tao,ZHENG Honglei,CHEN Congcong.Energy saving analysis of variable air volume and variable water quantity in central air-conditioning cooling water system[J].Industrial Instrumentation & Automation,2018,(06):7-11.[doi:1000-0682(2018)06-0000-00]
点击复制

中央空调冷却水系统变风量变水量节能性分析

《工业仪表与自动化装置》[ISSN:1000-0682/CN:61-1121/TH]

卷:
期数:
2018年06期
页码:
7-11
栏目:
出版日期:
2018-12-15

文章信息/Info

Title:
Energy saving analysis of variable air volume and variable water quantity in central air-conditioning cooling water system
作者:
张 涛郑鸿磊陈聪聪
青岛科技大学 自动化与电子工程学院,山东 青岛 266061
Author(s):
ZHANG Tao ZHENG Honglei CHEN Congcong
College of Automation and Electronics Engineering,Qingdao University of Science & Technology, Shandong Qingdao 266061, China
关键词:
空调冷却水系统动态仿真平台变风量变水量
Keywords:
air condition cooling water system dynamic simulation platform variable air volume variable water volume
分类号:
TB6
DOI:
1000-0682(2018)06-0000-00
文献标志码:
A
摘要:
为了降低中央空调冷却水系统的能耗,设计了一种变风量、变水量运行的冷却水系统。根据实测数据建立了中央空调冷却水系统的数学模型,并在此基础上,基于TRNSYS动态仿真软件,建立了中央空调冷却水系统的动态仿真平台。通过对冷却水系统的运行仿真,并分析了变风量、变水量运行的节能效果和运行方式。通过与传统的定风量、定水量运行的中央空调冷却水系统对比发现,变风量、变水量运行能够取得更好的节能效果。
Abstract:
In order to reduce the energy consumption of the central air-conditioning cooling water system, a cooling water system with variable air volume and variable water volume was designed.Based on the measured data, the mathematical model of the central air-conditioning cooling water system was established, and on this basis, a dynamic simulation platform for the cooling water system of the central air conditioning is set up based on TRNSYS dynamic simulation software. Through the simulation of the cooling water system, and the energy saving mode and operation effect of variable air volume and variable water volume were analyzed. Compared with the traditional central air-conditioning cooling water system which operates with the constant amount of air and constant water volume, variable air volume and variable water volume operation can achieve better energy-saving effect.

参考文献/References:

[1] 钟震西.中央空调冷却水系统节能控制的研究[D].上海:上海交通大学, 2011.

[2] 刘洋.基于TRNSYS的中央空调冷却水系统节能优化仿真研究[D].广州:华南理工大学,2013.
[3] 曹旦.中央空调系统仿真与节能优化[D].上海:东华大学, 2016.
[4] 孙一坚.关于集中空调冷却水系统节能运行——评《节能不能因小失大》[J].暖通空调,2003, 33(2):39-39.
[5] 胡磊,卢军,陈明,等.集中空调冷却水变流量节能研究[J].暖通空调,2011,41(9):137-140.
[6] 曲凯阳,胡德祥,王连吉,等.空调冷却水系统最优节能控制策略[J].暖通空调,2010, 40(4):110-114.
[7] 周洪煜,陈小健,陈孜虎.变水量与变风量的中央空调节能控制策略[J].控制工程,2011, 18(3):474-478.
[8] 王亮,卢军,陈明,等.空调系统冷水泵并联变频优化运行[J].暖通空调,2011,41(12):114-116.
[9] 季科,张永贵,刘冰冰,等.基于 TRNSYS 的空调水系统仿真平台[J].暖通空调,2015(5):93-96.
[10] 胡玮,陈立定.基于Trnsys的水冷型中央空调系统建模与仿真[J].系统仿真技术,2011, 07(3):218-222.