|本期目录/Table of Contents|

[1]吴 瀛,刘 佳,周会宾,等.一种数字化电能表的现场快速校验方法[J].工业仪表与自动化装置,2021,(03):67-70.[doi:10.19950/j.cnki.cn61-1121/th.2021.03.013]
 WU Ying,LIU Jia,ZHOU Huibin,et al.A field fast calibration method of digital watt-hour meter[J].Industrial Instrumentation & Automation,2021,(03):67-70.[doi:10.19950/j.cnki.cn61-1121/th.2021.03.013]
点击复制

一种数字化电能表的现场快速校验方法

《工业仪表与自动化装置》[ISSN:1000-0682/CN:61-1121/TH]

卷:
期数:
2021年03期
页码:
67-70
栏目:
出版日期:
2021-06-15

文章信息/Info

Title:
A field fast calibration method of digital watt-hour meter
作者:
吴 瀛1刘 佳2周会宾3赵进全3罗文杰3
1. 中国南方电网有限责任公司超高压输电公司 检修试验中心,广东 广州 510663;
2. 中国电力科学研究院有限公司,北京 100192;3. 西安交通大学 电气工程学院,陕西 西安 710049
Author(s):
WU Ying1 LIU Jia2 ZHOU Huibin3 ZHAO Jinquan3 LUO Wenjie3
1. Extra High Voltage Power Transmission Company, China Southern Power Grid, Guangdong Guangzhou 510663, China;
2. China Electric Power Research Institute, Beijing 100192, China;
3. School of Electrical Engineering, Xi’an Jiaotong University, Shaanxi Xi’an
关键词:
数字化电能表标准数字表法现场快速校验DSP高频数字采样
Keywords:
digital watt-hour meter standard digital watt-hour meter method field fast calibration DSP high-frequency digital sampling
分类号:
TM933
DOI:
10.19950/j.cnki.cn61-1121/th.2021.03.013
文献标志码:
A
摘要:
随着数字化电能表在变电站中的应用日益广泛,现场校验需要准确高效的校验方法。针对目前数字化电能表校验方法存在检测速度慢的问题,提出了一种数字化电能表快速校验方法。该方法基于标准表法,通过标准表与数字功率源的集成,利用DSP高频数字采样输出高频电能脉冲,缩短校验时间。对于现场安装的0.2级数字表,当数字采样频率达到16 kHz时,算法误差不超过0.01%,一个测量点的测量时间仅为0.63 s,极大地减小了数字化电能表现场校验的时间。
Abstract:
With the increasing application of digital watt-hour meter in substation,accurate and efficient calibration method is needed for field calibration.Aiming at the problem of slow detection speed in the current digital watt-hour meter calibration method,a fast calibration method of digital watt-hour meter is proposed.This method is based on the standard meter method.Through the integration of the standard meter and the digital power source,the DSP high-frequency digital sampling is used to output the high-frequency power pulse,which shortens the calibration time.For the 0.2 digital meter installed on site, when the digital sampling frequency reaches 16 kHz,the algorithm error is not more than 0.01%, and the measurement time of a measurement point is only 0.63 s,which greatly reduces the time of field calibration of digital watt-hour meter.

参考文献/References:

[1] 郑磊,曾妍,杨剑,等.数字化电能表校验方法及校验装置研究[J].电测与仪表,2017,54(17):100-105.

[2] 艾兵,江波.数字电能计量及其电能表检测技术[J].四川电力技术,2011,34(02):10-13+17.
[3] 肖勇,江波,赵伟,等.基于IEC61850标准的数字电能表检定技术研究进展[J].电测与仪表,2014,51(01):1-6.
[4] 唐毅,江波,李红斌,等.数字电能计量系统检定方法综述 [C].天津:2013年全国电气工程博士后学术论坛,2013,28(S2):372-377.
[5] 电力行业电测量标准化技术委员会.数字化电能表校准规范:DL/T 1507—2016[S].2016.
[6] 周文斌,李红斌,蒋紫娟,等.基于标准电能表高频脉冲的数字化电能表快速校验方法[J].电测与仪表,2019, 56(23):125-131.
[7] 电力行业电测量标准化技术委员会.数字化电能表技术规范:T/CEC 116—2016[S].2016.
[8] 曾妍.数字化电能表计量准确度校验装置研究[D].武汉:华中科技大学,2016.
[9] 唐登平,李俊,郑欣,等.适用于复杂工况的高性能标准数字化电能表[J].电测与仪表,2018,55(22):140-146.
[10] 罗南星.误差理论与数据处理[M].北京:机械工业出版社,2015:214.

相似文献/References:

备注/Memo

备注/Memo:
收稿日期:2020-11-10

作者简介:
吴瀛(1981),女,广东省梅州市人,硕士,高级工程师,主要从事电能计量研究。
更新日期/Last Update: 1900-01-01