|本期目录/Table of Contents|

[1]康 勇,李 靖,丁 凌,等.基于介质可压缩性的涡街流量计仪表系数修正[J].工业仪表与自动化装置,2023,(02):96-100+106.[doi:10.19950/j.cnki.cn61-1121/th.2023.02.019]
 KANG Yong,LI Jing,DING Ling,et al.Modification of meter coefficient of vortex flowmeter based on compressibility of medium[J].Industrial Instrumentation & Automation,2023,(02):96-100+106.[doi:10.19950/j.cnki.cn61-1121/th.2023.02.019]
点击复制

基于介质可压缩性的涡街流量计仪表系数修正

《工业仪表与自动化装置》[ISSN:1000-0682/CN:61-1121/TH]

卷:
期数:
2023年02期
页码:
96-100+106
栏目:
出版日期:
2023-04-15

文章信息/Info

Title:
Modification of meter coefficient of vortex flowmeter based on compressibility of medium
文章编号:
1000-0682(2023)02-0096-05
作者:
康 勇1李 靖1丁 凌1段飞飞1王荣杰2周秉直1
1.陕西省计量科学研究院, 陕西 西安 710100;
2.福标测量仪表(上海)有限公司,上海 200131
Author(s):
KANG Yong1LI Jing1 DING Ling1DUAN Feifei1WANG Rongjie2ZHOU Bingzhi1
1. Shaanxi Institute of Metrology Science, Shaanxi Xi’an 710100, China;
2. Flowmaster measurement Instruments (Shanghai) Co., LTD., Shanghai, 200131, China
关键词:
涡街流量计仪表系数数值分析修正公式介质可压缩性
Keywords:
vortex flowmetermeter coefficientnumerical analysismodified equationfluid compressibility
分类号:
TB937
DOI:
10.19950/j.cnki.cn61-1121/th.2023.02.019
文献标志码:
A
摘要:
基于涡街流量计基本原理,结合流体力学分析了介质可压缩性对涡街流量计计量特性的影响。考虑到涡街流量计流动截面突然改变导致流体介质参数发生改变的现象与差压式流量计有相似之处,类比标准孔板的介质可膨胀性系数经验公式提出基于介质可压缩性的涡街流量计仪表系数修正数学模型。通过最小二乘拟合对实流标定实验数据进行数值分析得到仪表系数的可压缩性修正公式。最后分析了修正仪表系数的误差和不确定度,最大误差为 -0.64%,相对扩展不确定度均在1%以内。研究结果对采用蒸汽介质的涡街流量计仪表系数跨介质标定具有指导意义。
Abstract:
The influence of medium compressibility on the measurement characteristics of vortex flowmeter was analyzed based on the principle of vortex flowmeter combined with fluid mechanics. Considering the similarity between the vortex flowmeter and the differential pressure flowmeter in the phenomenon that the parameters of the fluid medium changed due to the suddenly change of the cross-section, a modified mathematical model of meter coefficient of vortex flowmeter based on compressibility of medium is proposed which is derived from the empirical formula of expansibility coefficient of standard orifice plate. The compressibility modification equation of the meter coefficient is obtained by the numerical analysis of the experimental data through the least square method. At the end of the paper, the error and uncertainty of the modified meter coefficient are analyzed, the result shows that the maximum error is -0.64% , and the relative expanded uncertainty are less than 1% . The results can be used to calibrate the cross-medium meter coefficient of vortex flowmeter with steam medium.

参考文献/References:

[1]姜仲霞,姜川涛,刘桂芳.涡街流量计[M].北京:中国石化出版社,2005.

[2]郑灿亭.浅议以可压缩空气代替蒸汽进行蒸汽流量计的检定[J].炼油化工自动化,1996 (01):63-66.?/div>
[3]顾永伟,苏黎丽,陈躬炎,等.涡街流量计的空气标定和蒸汽实流测试对比分析[J].自动化仪表,2019,40(12):72-75+79.
[4]徐立毅.引起涡街流量计仪表系数变化的因素及解决措施[J].计量技术,2018(04):26-28.
[5] VERSHININ V E, POLKOVNIKOV F I.Numerical Investigation of the Influence of Bluff Body’s Shape on Flow Characteristics in Vortex Flowmeters[J].Automation and Remote Control,2019,80(07):1368-1373.
[6]许文达,张涛,毕英,等.气体可压缩性对涡街流量计计量性能影响分析[J].电子测量与仪器学报,2013,27(09):797-802.?div>[7]许文达,张涛,毕英,等.蒸汽对涡街流量计计量特性影响分析[J].天津大学学报,2014,47(08):683-688.?/div>
[8]苏庆文,许文达,李宝,等.涡街流量计在蒸汽、空气及水介质下的仿真分析[J].工业计量,2015,25(02):21-24.?div>[9]许文达,张涛,毕英,等.涡街流量计在不同介质下的比对试验研究[J].中国计量,2019(04):73-76.
[10]日本工业标准调查会.涡街流量计——流量测定方:法JIS Z 8766:2002[S].2002.
[11]British Standard. ISO 5167-2:.Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular Cross-section Conduits Running[S].2003.
[12]欧阳洁,聂玉峰,车刚阳,等.数值分析[M].北京:高等教育出版社,2009.
[13]李靖,康勇,韩冰,等.不同介质下涡街流量计计量性能分析[J].仪器仪表标准化与计量,2022(05):28-31+37.
[14]李春辉,李鹏.作为标准表非定点使用的涡轮流量计评定方法探析[J].计量学报,2015,36(06):610-612.

相似文献/References:

[1]刘 波,李理光,刘 庆,等.基于最小二乘法的脉冲流量计仪表系数的非线性修正[J].工业仪表与自动化装置,2015,(01):3.
 LIU Bo,LI Liguang,LIU Qing,et al.Based on the least square method of pulse flowmeter instrument coefficient of non-linear correction[J].Industrial Instrumentation & Automation,2015,(02):3.
[2]黎 翱,左志涛,徐 冉,等.基于大容量内存单片机的涡街流量变送器研制[J].工业仪表与自动化装置,2021,(03):3.[doi:10.19950/j.cnki.cn61-1121/th.2021.03.001]
 LI Ao,ZUO Zhitao,XU Ran,et al.Large memory microcontroller based design for vortex flow transmitter[J].Industrial Instrumentation & Automation,2021,(02):3.[doi:10.19950/j.cnki.cn61-1121/th.2021.03.001]

备注/Memo

备注/Memo:
收稿日期:2023-01-08
基金项目:
陕西省市场监督管理局科技计划项目(2019KY01)
第一作者:
康勇(1982—),男,汉族,陕西西安人,硕士研究生,高级工程师。研究方向为流量计量。
通信作者:
周秉直(1965—),男,汉族,陕西西安人,学士,正高级工程师。主要从事流量、热能计量研究工作。