|本期目录/Table of Contents|

[1]孙 南,姜昊罡,吕 珂,等.变频起动及固态降补起动在大型电机的应用[J].工业仪表与自动化装置,2023,(03):117-121.[doi:10.19950/j.cnki.cn61-1121/th.2023.03.023]
 SUN Nan,JIANG Haogang,LV Ke,et al.Application of variable frequency soft starting and solid state drop starting to large motor[J].Industrial Instrumentation & Automation,2023,(03):117-121.[doi:10.19950/j.cnki.cn61-1121/th.2023.03.023]
点击复制

变频起动及固态降补起动在大型电机的应用

《工业仪表与自动化装置》[ISSN:1000-0682/CN:61-1121/TH]

卷:
期数:
2023年03期
页码:
117-121
栏目:
出版日期:
2023-06-15

文章信息/Info

Title:
Application of variable frequency soft starting and solid state drop starting to large motor
文章编号:
1000-0682(2023)02-0117-06
作者:
孙 南 姜昊罡 吕 珂 刘勇涛
西安陕鼓动力股份有限公司,陕西 西安 710075
Author(s):
SUN Nan JIANG Haogang LV Ke LIU Yongtao
Xian Shaangu Power Co.,Ltd. , Shaanxi Xi’an 710075,China
关键词:
变频起动固态起动起动性能空分起动时间母线降压
Keywords:
variable frequency starting solid soft starting starting performance air separation starting time bus depressurization
分类号:
TM344.6
DOI:
10.19950/j.cnki.cn61-1121/th.2023.03.023
文献标志码:
A
摘要:
高压变频起动方式和高压固态降补起动方式是两种比较先进的降压起动方式,可以优化电机的起动参数、保护用户的电网性能、减少对机械设备的冲击、延长机械设备及电机的寿命。目前这两种起动方式广泛应用于10 kV电网负载当中,本文主要论述了高压变频起动方式及高压固态降补起动方式在空分领域的应用,两种起动方式的技术方案,工作原理,起动方式,容量计算、占地面积、成本、对电网参数影响等方面的对比等,通过深入对比分析,对高压电机起动方式选择有很大的参考价值。
Abstract:
The high voltage variable frequency soft starting mode and the high voltage solid supplementary starting mode are two relatively advanced step-down starting modes, which can optimize the starting parameters of the motor, protect the performance of the user’s power grid, reduce the impact on the mechanical equipment, and extend the life of the mechanical equipment and motor. At present, these two starting modes are widely used in 10 kV power grid load. This paper mainly discusses the application of high-voltage variable frequency soft starting mode and high-voltage solid-state supplementary starting mode in the field of air separation, the technical scheme, working principle, starting mode, capacity calculation, cover area, cost, impact on the power grid parameters and other aspects of comparison, through in-depth comparative analysis, It has great reference value for selecting the starting mode of high voltage motor

参考文献/References:

[1]阎强,金磊.高压变频技术的发展趋势[J].中国石油和化工标准与质量,2017(11):12-14.

[2]张延林,王鹏,韩英杰,等.变频电动机差动保护的研究与应用 [J].华电技术,2017(4):32-33.
[3]李艳东,李向前,韩锋,等.高线精轧机LCI变频传动系统稳定运行研究[J].电工材料,2021(03):56-57+62.
[4]何倩.烧结主抽风机高压变频改造研究与应用[J].电子测试,2021(2):41-43.
[5]林闻捷,濮力希,李军飞.大型空压机“一拖二”降补固态 起动改造[J].江西冶金,2019,39(5):33-36.?/div>
[6]刘介才,霍平.工厂供电[M].北京:机械工业出版社,2017.
[7]夏道止,杜正春.电力系统分析[M].北京:中国电力出版社,2018.
[8]陈金刚,黄莉明,张红枝.笼型三相异步电动机变极调速和变频调速解析[J].防爆电机,2018.5.37-39.
[9]王静海.电机起动相关问题分析[J].设备管理与维修,2019,8(4):137-138.
[10]张红枝,张雪雪,张志勇,等.低压笼型三相异步电动机起 动分析[J].防爆电机,2017,52( 5):23-28.