|本期目录/Table of Contents|

[1]李 鹏,杨 熹,陈 欣,等.单相智能电能表电池欠压故障分析[J].工业仪表与自动化装置,2017,(04):113-114.
 LI Peng,YANG Xi,CHEN Xin,et al.Analysis of the under voltage fault of single phase intelligent electric energy meter[J].Industrial Instrumentation & Automation,2017,(04):113-114.
点击复制

单相智能电能表电池欠压故障分析

《工业仪表与自动化装置》[ISSN:1000-0682/CN:61-1121/TH]

卷:
期数:
2017年04期
页码:
113-114
栏目:
出版日期:
2017-08-15

文章信息/Info

Title:
Analysis of the under voltage fault of single phase intelligent electric energy meter
文章编号:
1000-0682(2017)04-0000-00
作者:
李 鹏1杨 熹1陈 欣1高敬更1李 飒2
(1.国网甘肃省电力公司电力科学研究院;2.中国科学院近代物理研究所,兰州 730060)
Author(s):
LI Peng1 YANG Xi1 CHEN Xin1 GAO Jinggeng1 LI Sa2
(1.State Grid Gansu Electric Power Research Institute;2.Institute of Modern Physics Chinese Academy of Sciences, Lanzhou 730060, China)
关键词:
时钟电池抄表电池欠压掉电
Keywords:
clock battery meter reading battery loss power down power
分类号:
TM933.4
DOI:
-
文献标志码:
B
摘要:
单相智能电能表时钟电池与抄表电池共用一块电池。时钟电池为实时时钟模块、相应电路及器件提供电源的电池; 抄表电池保障电能表停电抄表、全失压和停电开盖检测等功能,并为相应电路及器件提供电源的电池。该文主要剖析单相智能电能表电池欠压故障对电能表运行产生的影响,分析单相智能电能表电池供电结构,查找电池欠压的主要原因,并建议厂家改进产品结构。
Abstract:
The clock battery and meter reading battery of Single phase intelligent electric energy meter share one cell. The clock battery provides power for the real time clock module and the corresponding circuit and other devices; when the meter loss power, the meter reading battery supports reading meter power meter, full woltage loss and power cut open cover detection and other functions, meanwhile the corresponding circuit and device provides power to the battery. This paper mainly analyzes the single phase intelligent electric watch battery undervoltage fault of electric energy meter running and analysis of single phase intelligent electric energy meter battery power supply structure, search battery undervoltage the main reason,and improve the product structure and recommended manufacturer.

参考文献/References:

[1] 郭丽娟.智能电能表全生命周期质量评价方法研究[D].北京:华北电力大学,2014.

[2] 计晓恰.智能电能表常见故障的研究与分析[D].北京:华北电力大学,2012.
[3] 黄艳,周文斌,吴晓豆,等.智能电能表的发展应用及误差调整[J].电侧与仪表,2012,49(10A):36-40.
[4] JJF1245.3—2010 安装式电能表型式评价大纲特殊要求静止式有功电能表(0.2S、0.5S、1级和2级)[S].北京:中国计量出版社,2010.