Title:
Remote intelligent control method of fan linkage system in substation environment
文章编号:
1000-0682(2022)01-0000-00
作者:
苏 君吴 昊周 琰
国网上海市北供电公司,上海 200072
Author(s):
SU Jun WU Hao ZHOU Yan
( State Grid shanghai Shibei Electric Power Supply Company,Shanghai, 200072, China)
关键词:
变电站环境风机联动系统远程控制PLCSocket网络变频器
Keywords:
substation environment fan linkage system remote control plc socket network frequency converter
分类号:
TH432
DOI:
10.19950/j.cnki.cn61-1121/th.2022.01.005
文献标志码:
A
摘要:
风机联动系统运行过程消耗大量电能,远程控制过程的目标电压、电流与功率等参数获取误差较大,对此,研究一种新的变电站环境风机联动系统远程智能控制方法。各类传感器采用交流采样的方式获取离散时间信号,在PLC控制下,经过模数转换器获取离散数据,通过相应过程处理离散数据获取电压、电流、有功/无功功率等运行参数,同预先设定的参数进行对比,根据实际应用需求,确定目标当前运行所需运行参数,在上位机端输入控制命令,通过Socket网络完成上位机端与PLC端的控制命令传输。PLC在接收到上位机传输的控制命令后,通过变频器完成变电站环境风机联动系统的远程智能控制。实例测试结果显示,该方法可准确采集测试对象运行参数,年节约电费达到87.19万元。
Abstract:
The wind turbine linkage system consumes a lot of electric energy in the operation process, and the acquisition errors of target voltage, current and power in the remote control process are large. Therefore, a new remote intelligent control method of wind turbine linkage system in substation environment is studied. Various sensors use AC sampling to obtain discrete-time signals. Under the control of PLC, discrete data are obtained through analog-to-digital converter, and discrete data are processed through corresponding processes to obtain operating parameters such as voltage, current, active / reactive power. Compared with preset parameters, the operating parameters required for the current operation of the target are determined according to the actual application requirements, Input the control command at the upper computer end, and complete the control command transmission between the upper computer end and the PLC end through the socket network. After receiving the control command transmitted by the upper computer, PLC completes the remote intelligent control of the substation environment fan linkage system through the frequency converter. The example test results show that this method can accurately collect the operation parameters of the test object, and the annual electricity cost can reach 871900 yuan.

参考文献/References:

[1]郭波.矿用局部通风机三级智能联控系统在高瓦斯矿井的应用[J].煤炭工程,2019,51(8):74-77.

[2]谭成.中心桥煤矿区域联动压风机监控系统[J].煤矿安全,2019,50(5):103-104+108.
[3]王凯,郝海清,蒋曙光,等.矿井火灾风烟流区域联动与智能调控系统研究[J].工矿自动化,2019,45(7):21-27.
[4]刘青,徐宏璐,李权.基于STATCOM/BESS强化风机VSG虚拟惯性的协同控制方法[J].电力系统保护与控制,2019,47(23):74-81.
[5]陈艳,黄灿英,罗小青,等.基于Buck电路的矩阵变换器风机直接转矩控制[J].沈阳工业大学学报,2019,41(01):19-24.
[6]高本锋,胡韵婷,李忍,等.基于自抗扰控制的双馈风机次同步控制相互作用抑制策略研究[J]. 电网技术, 2019, 43(02)655-664.
[7]张春芝.基于PLC和变频器的起重船电机自动控制系统[J]. 舰船科学技术,2020,42(20):217-219.
[8]张宏伟,吕雪霞.基于深度学习的发电厂变频器过压故障检测[J].电子设计工程,2021,29(5):71-74.
[9]周德华.矿用绕线式异步电机转子变频矢量控制系统研究[J].煤炭技术,2019,38(1):158-160.
[10] 谭继鑫,井永腾,郭昊,等.基于Boost变换的永磁同步电机变频电源电压谐波优化控制[J].电工技术学报,2020,35(21):4475-4482.
[11]韦文, 沈宇浩, 唐湛恒.基于工业以太网的除尘风机节能控制系统设计[J].烟草科技,2019,52(6):117-121.
[12]张亚军,张利平,郑 宣.智慧园区大规模能源监测数据通讯方法的优化及应用[J].工业仪表与自动化装置,2021,(04):135-138.
[13]周明,董哲,李洪宇,等.风机故障后有功控制对系统暂态功角失稳的影响机理[J].电网技术, 2019(4):1280-1293.
[14]李定华.海洋平台变频空调风机频率模糊控制系统[J].舰船科学技术,2019,41(18):214-216.
[15]黄景光,于楠,林湘宁,等.远程备用智能保护一体化中心架构通信系统连通可靠性研究[J].电力系统保护与控制,2019,47(24):65-75.
[16]马翔,董康田,郑金,等.离心风机变频调速运行中存在问题及解决方法[J].热力发电,2019,48(11):79-83.
[17]白全林.变频-旁路工频控制技术在主通风机上的应用[J]. 煤炭工程,2020,518(11):144-148.

相似文献/References:

备注/Memo

备注/Memo:
收稿日期:2021-10-21

作者简介:
苏君(1985),男,汉族,上海人,本科,工程师,研究方向为变电运维、配电运维检修、电气设备技改等。
更新日期/Last Update: 1900-01-01