|本期目录/Table of Contents|

[1]张明敏,柳义成.超短基线水声定位仪量值溯源方法研究[J].工业仪表与自动化装置,2022,(04):141-144.[doi:10.19950/j.cnki.cn61-1121/th.2022.04.029]
 ZHANG Mingmin,LIU Yichen.Research on quantity traceability method of ultra-short baseline hydroacoustic locator[J].Industrial Instrumentation & Automation,2022,(04):141-144.[doi:10.19950/j.cnki.cn61-1121/th.2022.04.029]
点击复制

超短基线水声定位仪量值溯源方法研究

《工业仪表与自动化装置》[ISSN:1000-0682/CN:61-1121/TH]

卷:
期数:
2022年04期
页码:
141-144
栏目:
出版日期:
2022-08-15

文章信息/Info

Title:
Research on quantity traceability method of ultra-short baseline hydroacoustic locator
文章编号:
1000-0682(2022)04-0000-00
作者:
张明敏柳义成
交通运输部天津水运工程科学研究所,天津 300456
Author(s):
ZHANG Mingmin LIU Yichen
Tianjin Research Institue for Water Transport Engineering, M.O.T, Tianjin 300456, China
关键词:
超短基线水声定位仪多维运行控制机构校准测量不确定度
Keywords:
ultra-short baseline hydroacoustic locator multidimensional operation control mechanism calibration measurement uncertainty
分类号:
TH71
DOI:
10.19950/j.cnki.cn61-1121/th.2022.04.029
文献标志码:
A
摘要:
超短基线水声定位仪不仅广泛应用于水运工程、港口航道保障及海洋工程调查等领域,在水下救险、海上救援搜寻、沉船打捞等方面也展现出得天独厚的优势。为了准确评价超短基线定位仪的测量性能,基于研发的多维运行控制机构,提出了超短基线水声定位仪斜距测量准确度的计量校准方法,并分析了校准结果的测量不确定度,论证了校准方法的可行性。结果表明,在100 m斜距条件下,测量不确定度U=0.20 m(k=2),满足测量不确定度合格判定的要求,为超短基线水声定位仪量值溯源提供了技术保障。
Abstract:
Ultra-short baseline hydroacoustic locator is not only widely used in the fields of water transportation engineering, port and channel guarantee and marine engineering investigation, but also shows unique advantages in underwater rescue, maritime rescue and search, sunken ship salvage and so on. In order to accurately evaluate the measurement performance of ultra-short baseline hydroacoustic locator, based on the multi-dimensional operation control mechanism developed, this study puts forward the metrological calibration method for the oblique distance measurement accuracy of ultra-short baseline hydroacoustic locator, analyzes the measurement uncertainty of the calibration results, and demonstrates the feasibility of the calibration method. The results show that under the condition of 100 m oblique distance, the measurement uncertainty is U =0.20 m (k = 2), which meets the requirements of qualified determination of measurement uncertainty, and provides a technical guarantee for the traceability of measurement value of ultra-short baseline hydroacoustic locator.

参考文献/References:

[1] 程谦,王英民,诸国磊.多子阵组合的短基线声学定位系统数据优化方法[J].应用声学,2019,38(4):742-749.

[2] Sun Dajun et al. Angular misalignment calibration method for ultra‐short baseline positioning system based on matrix decomposition[J]. IET Radar, Sonar & Navigation, 2019, 13(3):456-463.
[3] 金博楠,徐晓苏,张涛,等.超短基线定位技术及在海洋工程中的应用[J].导航定位与授时,2018,5(4):8-20.
[4] 杨元喜,徐天河,薛树强.我国海洋大地测量基准与海洋导航技术研究进展与展望[J].测绘学报,2017,46(1):1-8.
[5] Tan H P, Diamant R, Seah W K G, et al. A survey of techniques and challenges in underwater localization[J]. Ocean Engineering, 2011, 38(14-15):1663-1676.
[6] 杨保国.超短基线系统安装校准技术研究[D].哈尔滨:哈尔滨工程大学, 2013.
[7] 罗宇,施剑,王熙赢.基于最大似然估计的超短基线定位方法研究[A]//2019年全国声学大会论文集[C].中国声学学会, 2019.
[8] 刘长友.超短基线升降装置设计与研究[D].烟台:烟台大学,2013. DOI:10.7666/d.D432721.
[9] 牛清正.超短基线定位系统检测装置设计实现[D].哈尔滨:哈尔滨工程大学,2017.
[10] 全国水运专用计量器具计量技术委员会.超短基线水声定位仪检定规程:JJG(交通)152-2020.