|本期目录/Table of Contents|

[1]李 季,章吉刚,汪志远,等.超声波流量计整流器优化设计[J].工业仪表与自动化装置,2024,(01):38-41+56.[doi:DOI:10.19950/j.cnki.CN61-1121/TH.2024.01.009]
 LI Ji,ZHANG Jigang,WANG Zhiyuan,et al.Optimal design of rectifier for ultrasonic flow meters[J].Industrial Instrumentation & Automation,2024,(01):38-41+56.[doi:DOI:10.19950/j.cnki.CN61-1121/TH.2024.01.009]
点击复制

超声波流量计整流器优化设计(PDF)

《工业仪表与自动化装置》[ISSN:1000-0682/CN:61-1121/TH]

卷:
期数:
2024年01期
页码:
38-41+56
栏目:
出版日期:
2024-02-15

文章信息/Info

Title:
Optimal design of rectifier for ultrasonic flow meters
文章编号:
1000-0682(2024)01-0038-04
作者:
李 季章吉刚汪志远魏佳敏
(浙江威星智能仪表股份有限公司,浙江 杭州 311112)
Author(s):
LI JiZHANG JigangWANG ZhiyuanWEI Jiamin
(ZheJiang Viewshine High-Tech Co.Ltd.,Zhejiang Hangzhou 310013,China)
关键词:
整流器测量误差流态畸变气体超声波流量计弯管数值仿真
Keywords:
rectifier measurement error flow distortion gas ultrasonic flow meter elbow numerical simulation
分类号:
TH814
DOI:
DOI:10.19950/j.cnki.CN61-1121/TH.2024.01.009
文献标志码:
A
摘要:
气体超声波流量计的测量精度由飞行时间的测量精度和流量计自身的流场适应性决定,流量计的流场适应性又由流量计的声道布置和整流器的性能决定。文章设计了一种内嵌于流量计的整流器,详细阐述了该整流器的结构、各模块的功能。介绍了整流器性能优化的理论依据、过程以及整流器性能优劣的判别准则。该整流器性能优化主要取决于起旋器的优化,文章给出了装有8片起旋器和装有10片起旋器的整流器在直管、单弯管下的性能参数对比,试验结果显示装有10片起旋器的整流器有着更好的流场适应性:重复性满足国标要求,直管示值误差与弯管示值误差的差值<0.3%。文章的创新点在于给出气体超声波流量计整流器设计和优化的理论依据和一整套流程,对于设计气体超声波流量计整流器的科研人员有借鉴意义。
Abstract:
The measurement accuracy of gas ultrasonic flow meters is determined by the measurement accuracy of flight time and the adaptability of the flow field of the flow meter itself, the flow field adaptability of the flow meter is determined by the sound channel arrangement of the flow meter and the performance of the rectifier. The article designs a rectifier embedded in a flow meter, the structure of the rectifier,the functions of each module. This article introduces the theoretical basis, process, and criteria for evaluating the performance of rectifiers. The performance optimization of the rectifier mainly depends on the optimization of the spinner, the article provides a comparison of performance parameters between rectifiers equipped with 8 gyrators and rectifiers equipped with 10 gyrators under straight and single bend conditions, the experimental results show that rectifiers equipped with 10 spinners have better flow field adaptability: repeatability meets national standard requirements, the difference between the indication error of straight pipes and the indication error of bent pipes is less than 0.3%. The innovation of the article lies in providing the theoretical basis and a complete process for the design and optimization of a gas ultrasonic flow meter rectifier, it can help the researchers who design the ultrasonic flow meter rectifiers.

参考文献/References:

[1] 鲍敏.影响气体超声波流量计计量精度的主要因素研究[D].杭州:浙江大学,2004.

[2] 陈炜刚.气体超声波流量计非理想流场分析与补偿方法[D].杭州:浙江大学,2015.
[3] 田顺佳.不同整流器对超声波流量计计量的影响[J].油气储运,2021,40(7):780-790.
[4] 章圣意.气体超声波流量计整流装置设计与仿真分析[J].自动化仪表,2021,42(3):8-11.
?5] 万勇.CFD流动调整器性能评价方法研究[J].中国测试,2016,42(6):33-36.?/div>
?6] 陈红.超声波流量计整流器设计及验证[J].自动化仪表,2018,39(7):91-94.
[7] 用气体超声流量计测量天然气流量:GB/T 18604-2014 [S].2014.
[8] 熊光德.流动调整器对气体流量计量的影响[J].天然气与石油,2009,27(4):34-37.?/div>
[9] 杨运旅.基于CFD的流动调整器性能评价方法研究与安装优化[D].广州:华南理工大学,2017.
[10] 陈国宇.超声流量计声道设计与调整器流场优化方法研究[D].广州:华南理工大学,2018.?/div>
[11] 厉胜男.气体超声波流量计流场分析及整流器设计[D].成都:电子科技大学,2021.
[12] 朱国俊.典型扰流流场对超声流量计计量性能的影响研究[D].北京:北京化工大学,2022.
[13] 姚平.复杂流场下气体超声波流量计测量精度提升方法[D].杭州:浙江大学,2018.

相似文献/References:

[1]黄天富,王春光,吴志武,等.电容式电压互感器测量误差自适应校正方法[J].工业仪表与自动化装置,2022,(06):79.[doi:10.19950/j.cnki.cn61-1121/th.2022.06.015]
 HUANG Tianfu,WANG Chunguang,WU Zhiwu,et al.Adaptive correction method for measurement error of capacitive voltage transformer[J].Industrial Instrumentation & Automation,2022,(01):79.[doi:10.19950/j.cnki.cn61-1121/th.2022.06.015]

备注/Memo

备注/Memo:
收稿日期:2023-05-23第一作者:章吉刚(1983—),男,硕士,中级工程师,浙江嵊州人,主要从事超声测流技术研究。E-mail:zhang-593@163.com
更新日期/Last Update: 1900-01-01